Frozen Furnace Vent Pipes and Condensate Problems: Safe Checks for Denver Homes
If your furnace quit during or right after a snowstorm, or you've found water on the floor around it, the cause is often simple: a high-efficiency furnace's outdoor plastic vent pipes are blocked by snow or ice, or its condensate drain is clogged or frozen. Either one trips a safety switch and shuts the burners off. Some of this you can check safely yourself. The rest is a job for a technician. Call JC Mechanical any time at (720) 779-7263. We answer 24/7.
Do you have a high-efficiency furnace?
This guide is for high-efficiency (condensing) gas furnaces. You probably have one if:
- Two white or gray plastic (PVC) pipes run from the furnace and out through a side wall or the roof, instead of one metal flue into a chimney.
- There's a small plastic drain tube coming off the furnace that runs to a floor drain, a sink, or a small pump.
These furnaces pull so much heat out of the exhaust that it cools down and turns to water. That's normal. The water has to drain away, and the outside pipes have to stay clear for the furnace to run.
If your furnace vents through a metal pipe into a chimney, the snow-on-PVC problem doesn't apply. Try our furnace won't turn on checklist instead.
Why Denver winters cause this
- Drifting snow. Side-wall pipes often sit a foot or two above the ground. A wind-driven Front Range storm can bury them or pack the openings.
- Frost and ice buildup. The exhaust is warm and wet. On very cold nights that moisture can freeze around the pipe opening and slowly close it off.
- Cold drain lines. A condensate line that runs through a cold garage, crawlspace or outside wall can freeze, and a frozen line backs up just like a clogged one.
- Long cold snaps. The furnace runs longer, makes more water, and gives every small problem a chance to show up.
Safe checks you can do
- Look at the outdoor pipes. Find where the two plastic pipes leave the house. If snow is piled against them or packed into the openings, gently clear it by hand or with a soft broom. Clear a little space around them, too.
- Don't chip at ice. If the openings are coated in ice, don't hit or pry at them. The pipes can crack, and a cracked exhaust pipe is a safety problem. Don't use a torch, heat gun or open flame. Call us.
- Check the drain tube. Look for the small tube running from the furnace to a drain or pump. Is there water pooled under the furnace? Is the tube kinked, pulled loose, or running somewhere cold? Note what you see.
- Check the condensate pump (if you have one). It's a small box with a tank, usually on the floor next to the furnace. If it's full and not running, check that it's plugged in. Don't open it up or bypass its switch.
- Reset once, then stop. After clearing snow, turn the thermostat down, wait a minute, set it back to Heat, and give the furnace a few minutes to start. If it doesn't come back on, or it shuts down again, don't keep resetting it. Call (720) 779-7263.
- Keep pipes clear for the rest of the storm. After a big snow, check them again in the morning and after any drifting wind.
Pipes are clear and it still won't run? Call JC Mechanical at (720) 779-7263.
What's going on: causes and who should fix them
| What you notice | Likely cause | DIY or pro |
|---|---|---|
| Furnace stopped during or right after a snowstorm | Snow blocking the outdoor intake or exhaust pipe trips a safety (pressure) switch | Gently clear snow by hand. Call if it doesn't restart |
| Ice or frost ring around the exhaust pipe opening | Exhaust moisture freezing on very cold nights; sometimes a pipe slope or termination problem | Don't chip it. Call |
| Fan runs, then the furnace stops before it lights, over and over | Blocked vent, blocked drain, or a failing part keeping the safety switch from closing | Clear snow, then call |
| Water on the floor around the furnace | Clogged or frozen condensate drain, loose or cracked drain tube, or a failed condensate pump | Check the tube and pump power. Call for the fix |
| Gurgling or sloshing sound from the furnace | Water backing up in the condensate trap or drain | Pro |
| Condensate pump full and running nonstop, or not running at all | Pump or float switch problem, or a blocked line after the pump | Check it's plugged in. Then call |
| Furnace starts and stops repeatedly in cold, windy weather | Vent pipes frosting or a venting problem | Check the pipes. Then call. See short cycling |
| CO alarm sounds, or people feel sick | Combustion gases not venting properly | Leave the house. Call 911 from outside |
Not sure which row fits? Call (720) 779-7263 and tell us what you see. We answer 24/7.
What not to do
- Don't chip, hammer or melt ice on the pipes with a torch, heat gun or open flame.
- Don't block, cover or extend the outdoor pipes with buckets, boxes, tarps or "snow guards" you made yourself. That can make venting worse.
- Don't bypass or tape a safety switch, and don't unplug the condensate pump's switch wire.
- Don't pour hot water or chemicals into the furnace drain or trap.
- Don't heat the house with a gas oven, stove, grill or unvented heater. That can put carbon monoxide in your home. Use electric space heaters only as directed, plugged into a wall outlet and kept away from bedding and curtains.
Is it an emergency?
Call now if the furnace is off and the house is getting cold in freezing weather, if someone at home is an infant, an older adult or medically fragile, if water is spreading toward finished floors or electrical equipment, or if you see ice building on the exhaust pipe. CO alarm or symptoms: follow the safety box above first.
It can often wait until normal hours if you cleared snow and the furnace is running normally again, or if there's only a small amount of water and the house is staying warm. If you're not sure, call anyway. We answer 24/7. For a whole-house no-heat night, see our emergency furnace repair guide.
What happens when you call JC Mechanical
Call (720) 779-7263 and tell us what you've already checked: whether there was snow on the pipes, whether there's water around the furnace, and any blinking light pattern on the furnace. A JC technician finds the cause before recommending anything. We tell you what we found and give you options and the cost before any work begins. You decide what gets done.
JC Mechanical has served the south Denver metro since 2019. Learn more about us or see our furnace repair service.
Pricing and hours
- Service call: $89, 7am-7pm.
- Hours: office hours Mon-Sat, 7am-7pm. We answer 24/7.
- 24/7 service available. After-hours calls carry a higher service fee that is not applied to the repair. We'll tell you the amount before we come out.
- Repairs: we tell you the cost and give you options before any work.
- Prevent it next winter: our furnace safety inspection and maintenance plan are a good time to have the condensate drain, trap and vent pipes looked at before the snow flies.
Areas we cover
We serve homes across the south Denver metro, including Littleton, Centennial, Highlands Ranch, Englewood, Lone Tree, Greenwood Village, south and central Denver, Lakewood and Parker. See all service areas.
Frozen vent pipes and condensate: FAQ
Why did my furnace stop working after it snowed?
If you have a high-efficiency furnace with plastic pipes outside, snow or ice may be blocking them. The furnace senses the blockage and shuts itself off for safety. Gently clear snow by hand, wait a few minutes, and if it doesn't restart, call (720) 779-7263.
Can I melt ice off my furnace vent pipe?
Don't use a torch, heat gun or open flame, and don't chip at it. The pipes can crack. Brush loose snow away by hand. If ice is built up on the opening, call a technician.
Why is my furnace leaking water?
High-efficiency furnaces make water as they run, and it normally drains away through a small tube. If that drain, the trap, or the condensate pump clogs, freezes or fails, the water backs up and can leak onto the floor. The same problem often shuts the furnace off.
Can a frozen condensate line stop my furnace?
Yes. When the drain can't empty, a safety switch stops the burners so water doesn't back up into the furnace. That's why a frozen or clogged drain can leave you with no heat.
Is a blocked furnace vent dangerous?
It can be. A blocked exhaust pipe can push combustion gases back into the home. Most furnaces shut down first, but you should have working CO alarms. If an alarm sounds or anyone feels sick, leave the house and call 911 from outside.
How do I keep my furnace pipes from getting blocked?
Keep snow cleared away from the outdoor pipes after every storm, don't stack anything near them, and have the drain, trap and venting checked during your yearly furnace safety inspection.
Does every furnace have this problem?
No. Only high-efficiency (condensing) furnaces with plastic vent pipes make condensate and vent through the wall or roof this way. Older furnaces vent through a metal flue.
What will it cost to fix?